PRODUCT
Precision filter
发表时间:2014-9-23  文字 〖 〗  阅读次数:1234   [关闭窗口]
0

One, product introduction:

FJ series of compressed gas filter is designed according to the requirements of the international standard, with USA type HANKISON filter, shell is made of high quality aluminum alloy or carbon steel materials, the use of advanced processing technology, elegant appearance, quality with USA HANKISON products, accord with the international standard ISO8573.1-2001 compressed air quality. The pollutant removal ability, low pressure drop. You know, every increase of the pressure drop of 0.14kgf/cm2, power input will be increased by 1%. The filter during the specified lifetime always remain in the low pressure level and not be saturated, and according to the requirements of the annual regular maintenance, air quality assurance will be automatically extended for one year.

Note: filter must be regularly or differential pressure gauge pointer replacement in the red zone, avoid excessive blocking filter and caused a lot of pressure drop.

Two, design features:

FJ12 ~ FJ-36

FJ12 ~ FJ-36

And the circulation path to expand, to minimize pressure drop.

- shell is made of high quality aluminum alloy manufacture.

And the internal and external coating of epoxy resin powder, to improve durability and corrosion resistance.

And import and export through a screw thread, and labeling of the air flow in the shell, and is easy to install.

O type sealing ring.
And the rib type casing, facilitate the use of bent spanner.

And the pressure differential gauge suggest the best time - replacing the filter core can improve the investment efficiency and decrease the filter pressure drop (optional).

Work pressure is 0.1-1.3Mpa, the operating temperature is less than or equal to 66 DEG C

More than FJ-40 filter

- shell with high quality carbon steel or stainless steel material, flange mounting.

And the internal and external surface antirust galvanized or electrophoresis processing, surface smooth and bright, durability and corrosion resistance.

Automatic drainage device with reliable operation and long service life of the AD402-04 or HAD20B or electronic type drainage device.

Work pressure is 0.1-1.0Mpa, the operating temperature is less than or equal to 66 DEG C, 6.4MPa following an order is received.

What is on time and the replacement of the filter element of the good?

And ensure the high quality of the compressed air

Protection of adsorption type dryer adsorption bed

Protection of downstream equipment, operation personnel and technology

And reduce the operation cost

And improve the productivity and profitability

Three, the filter provides high performance and low pressure drop, can choose five kinds of filter, for your design to ensure the required quality of gas supply system

Application guide for the filter class

Description

(CAGL, PNEUROP and ISO) performance (data)
The use of occasions

FJ9

Separation / filter

Mechanical separator and 3 micron coalescing filter filter

* a lot of liquid

* large particles of solid

Filter: 3 microns and larger solid and liquid particles; residual oil content 5ppm w/w ISO8573.1 a solid quality grade: Grade 3; oil content: 5 the maximum liquid level of the inlet load: 25000ppm w/w

* after cooler downstream

* directly for working point

FJ7
The competent Road

Filter

1 micron coalescing filters used for gas pipeline workshop the following equipment:

* tools

* motor

* cylinder

Filter: 1 micron and more solid and liquid particles; residual oil content 1ppm w/w ISO8573.1 a solid quality grade: Grade 2; oil content: 4 the maximum load level of the inlet liquid: 2000ppm w/w

* upstream - oil mist filter

* the adsorption type dryer downstream

* if the upstream cooling after installation

Device / separator is used for

The work point

FJ5 high efficient oil removing filter

Fine coalescing filters used for oil free air supply of industrial production

* spraying

* blow

* instrument

* control valve

Filter: 0.01 micron and more solid and liquid particles;

99.99+% oil mist; residual oil content of 0.01PPm w/w

ISO8573.1 quality grade solid: 1; oil content: 2

The maximum liquid inlet load: 1000ppm w/w

* upstream adsorption dryer

* freeze dryer downstream

* under pressure swing adsorption dr
Travel, for fine particle filter

* for point of use (if there is a small amount of liquid loads can be used)

FJ3 ultra efficient oil removing filter

Ultra fine coalescing filters used for oil free air supply key applications

* air contact products occasions

* transfer

* agitation

* electronic components manufacturing

* nitrogen replacement

Filter: 0.01 micron and more solid and liquid particles;

99.999+% oil mist; residual oil content of 0.001PPm w/w

ISO8573.1 quality grade solid: 1; oil content: 1

The maximum liquid inlet load: 100ppm w/w

* upstream adsorption dryer

* if you have a large number of liquid load,

7 level filtering should be used as a pre filter

* freeze dryer downstream

FJ1 oil deodorizing filter

Activated carbon filter for odorless air supply

* food and drug manufacturing

* the air to breathe

* gas processing

Filter: oil and gas; residual oil content of 0.003ppm w/w (oil gas) 0.01 microns and larger solid particles; ISO8573.1 quality grade a solid: 1; oil content: 1; upstream the inlet of the filter can not have liquid a 1 stage filter should be used, in addition to the oil filter and ultra high efficiency oil mist filter, preventing the liquid oil pollution

* high efficient oil removing filter downstream

Four, model description

XF to FJ above, code and flow to the sample data consistency



Six, work pressure correction coefficient

When the pressure is 0.7MPa, to determine the maximum flow, flow rate multiplied by the correction coefficient of available with minimum pressure at the inlet of the corresponding filter. Not according to the size of pipe filter should be chosen according to the flow rate and the inlet pressure.

Minimum inlet pressure

MPa

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1.1

1.2

1.3

1.4

1.5

1.6

1.7

1.8

1.9

2.0

修正系数

Correction coefficient

0.38

0.53

0.65

0.76

0.85

0.93

1.00

1.07

1.13

1.19

1.25

1.31

1.36

1.41

1.46

1.51

1.56

1.60

1.65

1.70

七、.空气质量/降压表

Filter class

The solid particles to the minimum

Residual oil component

The pressure drop under the condition of stable(kgf/cm2)

Micron

The weight of the ppm

Stem

Wet

FJ9

3

5

0.07

0.11

FJ7

1

1

0.07

0.14

FJ5

0.01

0.01

0.07

0.21

FJ3

0.01

0.001

0.14

0.42

FJ1

0.01

0.003

0.07

Not applicable

Note: data in the table is for reference only, please ask for drawings, engineering application.